Bernhard Grunwald
Responsible for noise forecasts, drawing on years of practice, and supports acoustic assessments and measurement reports.
We guide you to your goal professionally and quickly – with measurements and noise forecasts according to the applicable standards and your individual requirements.
Our staff are professionally connected – among others through the German Acoustical Society (DEGA) and its Noise Working Group (ALD), as well as in the Chamber of Engineers of Baden-Württemberg. In addition, the Centre has contributed to the DIN/VDI Standards Committee Acoustics, Noise Control and Vibration Engineering (NALS).
We carry out acoustic investigations, measurements and noise forecasts – from a single noise source to complex installations. They are based on the applicable standards and the current state of the art.
Every assessment is based on the specific situation on site: we determine the relevant acoustic parameters, assess them against the applicable guideline values and provide you with a reliable result as the basis for your next steps. We carry out measurement, analysis and assessment ourselves – so the results remain traceable throughout. For us, individual work and a fair, transparent pricing model go together.
Of course, we measure on site in the conventional way. In many cases, however, our self-developed loan devices are sufficient: we send them to you and carry out the measurement via remote access. This saves travel and effort – the final standard-compliant assessment is carried out with Class 1 instrumentation.
Measurement and analysis systems are systematically characterised against Class 1 reference instrumentation; the corresponding method documentation is available on request.
Our team combines engineering, measurement and analysis expertise with many years of assessment practice – we handle every assessment from a single source.
Responsible for noise forecasts, drawing on years of practice, and supports acoustic assessments and measurement reports.
Focuses on the physical side of acoustics – instrument and room acoustics and measurement technology as the basis of every assessment.
Develops our measurement systems and carries out the acoustic measurements – from the hardware to the finished assessment.
Responsible for data and signal processing – from preparing the measurement data to the analysis.
We work throughout Germany, with a focus on southern Germany and Baden-Württemberg. Here you can see an exemplary selection from our assessment practice.
For a wooden roller coaster in a German theme park, an acoustic investigation compared the noise emissions of the original track system with a newly installed steel rail profile. Reference and follow-up measurements were used to determine and compare the relevant sound emission parameters, a one-third-octave frequency analysis and the impulsiveness of train pass-bys before and after the conversion. In addition, sound propagation and level decrease with increasing distance were evaluated in order to derive representative level values.
For a planned self-service laundrette on the ground floor of an inner-city residential building, an acoustic noise forecast was prepared as part of the permit procedure. Based on the sound power levels of the machines and the building physics, it was demonstrated that the TA Lärm immission guideline values are reliably met in the flat above and at the outdoor receiver locations. The required noise control measures, including a suspended acoustic ceiling, were dimensioned from the results.
For a software office, an acoustic investigation according to TA Lärm was carried out after a tonal noise, described as a “hum”, was noticed in the offices, originating from the rooftop photovoltaic system with inverter. As the installation and the protected rooms are structurally connected, the indoor immission guideline values according to section 6.2 of TA Lärm were applied and checked by measurement. In addition, a one-third-octave analysis assessed the low-frequency noise exposure and prominent tones according to TA Lärm 7.3 in conjunction with DIN 45680.
Following a complaint from a neighbour, the building authority required proof that two unpermitted air conditioners, retrofitted on the gable of a residential building, comply with the TA Lärm immission guideline values. Based on the manufacturer's data and the local conditions, the noise immissions at the relevant protected receiver locations on the neighbouring property were determined and assessed. The investigation served to clarify on a technical basis whether the units cause unreasonable noise nuisance for the neighbourhood.
For an owner-occupied flat above a bar, an acoustic investigation was carried out after low-frequency noise, vibrations and information-bearing components such as music and voices were perceived as considerably disturbing, especially at night. As the bar and the flat are structurally connected, the indoor levels were measured and assessed against the indoor immission guideline values of TA Lärm no. 6.2. In addition, the low-frequency components were evaluated according to DIN 45680, the peak levels were assessed, and the structural sound insulation was appraised according to DIN 4109.
For a cultural centre with an indoor loudspeaker used to broadcast prayers, a noise measurement according to TA Lärm was carried out to assess the effects on the surrounding neighbourhood. Airborne sound measurements were taken at several representative receiver locations in the surrounding mixed-use area with protected residential use, using a substitute measurement point for one inaccessible location. The investigation served to establish whether the installation complies with the relevant immission guideline values under typical use.
Non-binding – or simply ask us any questions you still have.
We ship our loan devices in reusable packaging – compared with single-use boxes, this saves 94 % waste and 76 % CO₂ (verified by Ökopol).